Hero Image
Image
1 min
Gyproc Fire Rated Systems
Gyproc offers 2 fire rated ceiling systems - 60 min and 90 min for your peace of mind and safety. Dive into the differences between our two systems below and learn which system will work best for you.
Concealed Grid - Fire Rated: 60 & 90 Minute Systems
RhinoBoard® FireStop® 60 minute system:
Ceiling system consisting of 2 layers of RhinoBoard® FireStop® dB 15 mm fixed to primary framework consisting of Gypframe® Ultrasteel® 51mm stud suspended using 25 x 25 mm Gyproc galvanised steel angle
RhinoBoard® FireStop® 90 minute system:
Ceiling system consisting of 3 layers of RhinoBord® FireStop® dB 15 mm fixed to stud framework suspended using 25 x 25 mm Gyproc galvanised steel angle.
Fire Rated System Diagrams
Image
Concealed Grid 60 Minute System
Image
Concealed Grid 90 Minute System
Key Benefits
- Guaranteed straightness of long sections
- Improved accuracy
- Suspension from concrete or timber floor & purlins
- 60 Minutes Fire Rating tested in accordance with SANS 10122:2
- Quick and easy Leveling